help button home button JAMIA Bigger figures
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published November 26, 2002 as JAMIA PrePrint; doi:10.1197/jamia.M1042
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
M1042v1
10/2/213    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, K. P.
Right arrow Articles by Hu, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, K. P.
Right arrow Articles by Hu, J.
Journal of the American Medical Informatics Association 10:213-223 (2003)
© 2003 American Medical Informatics Association


Model Formulation

XML Schema Representation of DICOM Structured Reporting

K. P. Lee, PhD and Jingkun Hu, MS

Affiliations of the authors: Philips Research, Briarcliff Manor, New York.

Correspondence and reprints: K. P. Lee, PhD, Philips Research, 345 Scarborough Road, Briarcliff Manor, NY 10510; e-mail: <kp.lee{at}philips.com>.

Objective: The Digital Imaging and Communications in Medicine (DICOM) Structured Reporting (SR) standard improves the expressiveness, precision, and comparability of documentation about diagnostic images and waveforms. It supports the interchange of clinical reports in which critical features shown by images and waveforms can be denoted unambiguously by the observer, indexed, and retrieved selectively by subsequent reviewers. It is essential to provide access to clinical reports across the health care enterprise by using technologies that facilitate information exchange and processing by computers as well as provide support for robust and semantically rich standards, such as DICOM. This is supported by the current trend in the healthcare industry towards the use of Extensible Markup Language (XML) technologies for storage and exchange of medical information. The objective of the work reported here is to develop XML Schema for representing DICOM SR as XML documents.

Design: We briefly describe the document type definition (DTD) for XML and its limitations, followed by XML Schema (the intended replacement for DTD) and its features. A framework for generating XML Schema for representing DICOM SR in XML is presented next.

Measurements: None applicable.

Results: A schema instance based on an SR example in the DICOM specification was created and validated against the schema. The schema is being used extensively in producing reports on Philips Medical Systems ultrasound equipment.

Conclusion: With the framework described it is feasible to generate XML Schema using the existing DICOM SR specification. It can also be applied to generate XML Schemas for other DICOM information objects.




This article has been cited by other articles:


Home page
RadioGraphicsHome page
C. W. Arnold, A. A. T. Bui, C. Morioka, S. El-Saden, and H. Kangarloo
Informatics in Radiology: A Prototype Web-based Reporting System for Onsite-Offsite Clinician Communication
RadioGraphics, July 1, 2007; 27(4): 1201 - 1211.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
R. Hussein, U. Engelmann, A. Schroeter, and H.-P. Meinzer
DICOM Structured Reporting: Part 2. Problems and Challenges in Implementation for PACS Workstations
RadioGraphics, May 1, 2004; 24(3): 897 - 909.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Medical Informatics Association.