help button home button JAMIA Bigger figures
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published March 28, 2003 as JAMIA PrePrint; doi:10.1197/jamia.M1207
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
M1207v1
10/4/363    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wachter, S. B.
Right arrow Articles by Westenskow, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wachter, S. B.
Right arrow Articles by Westenskow, D.
Journal of the American Medical Informatics Association 10:363-372 (2003)
© 2003 American Medical Informatics Association


Research Paper

The Employment of an Iterative Design Process to Develop a Pulmonary Graphical Display

S. Blake Wachter, BS, Jim Agutter, MArch, Noah Syroid, MS, Frank Drews, PhD, Matthew B. Weinger, MD and Dwayne Westenskow, PhD

Affiliations of the authors: Medical Informatics, University of Utah, Salt Lake City, Utah (SBW); Architecture, University of Utah, Salt Lake City, Utah (JA); Anesthesiology, University of Utah, Salt Lake City, Utah (NS, DW); Cognitive Psychology, University of Utah, Salt Lake City, Utah (FD); Department of Anesthesiology, University of California, San Diego, and the San Diego Center for Patient Safety at the VA San Diego Medical Center, La Jolla, California (MBW).

Correspondence and reprints: S. Blaker Wachter, University of Utah, Department of Anesthesiology, 3C444 SOM, 30 North 1900 East, Salt Lake City, UT 84132-2304; e-mail: <blake{at}relia.net>.

Received for publication: 08/16/02; accepted for publication: 01/13/03.

Objective: Data representations on today's medical monitors need to be improved to advance clinical awareness and prevent data vigilance errors. Simply building graphical displays does not ensure an improvement in clinical performance because displays have to be consistent with the user's clinical processes and mental models. In this report, the development of an original pulmonary graphical display for anesthesia is used as an example to show an iterative design process with built-in usability testing.

Design: The process reported here is rapid, inexpensive, and requires a minimal number of subjects per development cycle. Three paper-based tests evaluated the anatomic, variable mapping, and graphical diagnostic meaning of the pulmonary display.

Measurements: A confusion matrix compared the designer's intended answer with the subject's chosen answer. Considering deviations off the diagonal of the confusion matrix as design weaknesses, the pulmonary display was modified and retested. The iterative cycle continued until the anatomic and variable mapping cumulative test scores for a chosen design scored above 90% and the graphical diagnostic meaning test scored above 75%.

Results: The iterative development test resulted in five design iterations. The final graphical pulmonary display improved the overall intuitiveness by 18%. The display was tested in three categories: anatomic features, variable mapping, and diagnostic accuracy. The anatomic intuitiveness increased by 25%, variable mapping intuitiveness increased by 34%, and diagnostic accuracy decreased slightly by 4%.

Conclusion: With this rapid iterative development process, an intuitive graphical display can be developed inexpensively prior to formal testing in an experimental setting.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
R. W. Albert, J. A. Agutter, N. D. Syroid, K. B. Johnson, R. G. Loeb, and D. R. Westenskow
A Simulation-Based Evaluation of a Graphic Cardiovascular Display
Anesth. Analg., November 1, 2007; 105(5): 1303 - 1311.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
J. J. Saleem, E. S. Patterson, L. Militello, S. Anders, M. Falciglia, J. A. Wissman, E. M. Roth, and S. M. Asch
Impact of Clinical Reminder Redesign on Learnability, Efficiency, Usability, and Workload for Ambulatory Clinic Nurses
J. Am. Med. Inform. Assoc., September 1, 2007; 14(5): 632 - 640.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
S. B. Wachter, K. Johnson, R. Albert, N. Syroid, F. Drews, and D. Westenskow
The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator
J. Am. Med. Inform. Assoc., November 1, 2006; 13(6): 635 - 642.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
S. T. Rosenbloom, A. J. Geissbuhler, W. D. Dupont, D. A. Giuse, D. A. Talbert, W. M. Tierney, W. D. Plummer, W. W. Stead, and R. A. Miller
Effect of CPOE User Interface Design on User-Initiated Access to Educational and Patient Information during Clinical Care
J. Am. Med. Inform. Assoc., July 1, 2005; 12(4): 458 - 473.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. M. Sanderson, M. O. Watson, and W. J. Russell
Advanced Patient Monitoring Displays: Tools for Continuous Informing
Anesth. Analg., July 1, 2005; 101(1): 161 - 168.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Agutter, F. Drews, N. Syroid, D. Westneskow, R. Albert, D. Strayer, J. Bermudez, and M. B. Weinger
Evaluation of Graphic Cardiovascular Display in a High-Fidelity Simulator
Anesth. Analg., November 1, 2003; 97(5): 1403 - 1413.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Medical Informatics Association.