help button home button JAMIA Hate scrolling?
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

First published February 24, 2006 as JAMIA PrePrint; doi:10.1197/jamia.M1925
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
M1925v1
13/3/309    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yu, C.
Right arrow Articles by Reifman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yu, C.
Right arrow Articles by Reifman, J.
J Am Med Inform Assoc. 2006;13:309-320. DOI 10.1197/jamia.M1925.
© 2006 American Medical Informatics Association


Application of Information Technology

A Method for Automatic Identification of Reliable Heart Rates Calculated from ECG and PPG Waveforms

Chenggang Yu, PhD, Zhenqiu Liu, PhD, Thomas McKenna, PhD, Andrew T. Reisner, MD and Jaques Reifman, PhD

Affiliations of the authors: Bioinformatics Cell, Telemedicine and Advanced Technology Research Center, US Army Medical Research and Materiel Command, Fort Detrick, MD (CY, ZL, TM, JR); Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA (ATR); Dr. Liu is currently with the Division of Biostatistics, Greenebaum Cancer Center and Department of Epidemiology and Preventive Medicine, University of Maryland Medical Center.

Correspondence and reprints: Jaques Reifman, PhD, U.S. Army Medical Research and Materiel Command MRMC/TATRC, 504 Scott Street, Ft. Detrick, MD 21702-5012; e-mail: <jaques.reifman{at}us.army.mil>.

Received for publication: 08/01/05; accepted for publication: 01/16/06.

Objective: The development and application of data-driven decision-support systems for medical triage, diagnostics, and prognostics pose special requirements on physiologic data. In particular, that data are reliable in order to produce meaningful results. The authors describe a method that automatically estimates the reliability of reference heart rates (HRr) derived from electrocardiogram (ECG) waveforms and photoplethysmogram (PPG) waveforms recorded by vital-signs monitors. The reliability is quantitatively expressed through a quality index (QI) for each HRr.

Design: The proposed method estimates the reliability of heart rates from vital-signs monitors by (1) assessing the quality of the ECG and PPG waveforms, (2) separately computing heart rates from these waveforms, and (3) concisely combining this information into a QI that considers the physical redundancy of the signal sources and independence of heart rate calculations. The assessment of the waveforms is performed by a Support Vector Machine classifier and the independent computation of heart rate from the waveforms is performed by an adaptive peak identification technique, termed ADAPIT, which is designed to filter out motion-induced noise.

Results: The authors evaluated the method against 158 randomly selected data samples of trauma patients collected during helicopter transport, each sample consisting of 7-second ECG and PPG waveform segments and their associated HRr. They compared the results of the algorithm against manual analysis performed by human experts and found that in 92% of the cases, the algorithm either matches or is more conservative than the human's QI qualification. In the remaining 8% of the cases, the algorithm infers a less conservative QI, though in most cases this was because of algorithm/human disagreement over ambiguous waveform quality. If these ambiguous waveforms were relabeled, the misclassification rate would drop from 8% to 3%.

Conclusion: This method provides a robust approach for automatically assessing the reliability of large quantities of heart rate data and the waveforms from which they are derived.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Medical Informatics Association.