help button home button JAMIA Hate scrolling?
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Devine, E. G.
Right arrow Articles by Curtis, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Devine, E. G.
Right arrow Articles by Curtis, A. C.
Journal of the American Medical Informatics Association 7:462-468 (2000)
© 2000 American Medical Informatics Association


Technology Evaluation

Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports

Eric G. Devine, PhD, Stephan A. Gaehde, MD, MPH and Arthur C. Curtis, MD, PhD

Affiliation of the authors: Boston Veterans Administration Medical Center, Boston, Massachusetts.

Correspondence and reprints: Eric Devine, PhD, Department of Psychology (116b), Boston Department of Veterans Affairs, 150 S. Huntington Avenue, Boston, MA 02130; e-mail: <devine.eric{at}boston.va.gov>.

Abstract Objective: To compare out-of-box performance of three commercially available continuous speech recognition software packages: IBM ViaVoice 98 with General Medicine Vocabulary; Dragon Systems NaturallySpeaking Medical Suite, version 3.0; and L&H Voice Xpress for Medicine, General Medicine Edition, version 1.2.

Design: Twelve physicians completed minimal training with each software package and then dictated a medical progress note and discharge summary drawn from actual records.

Measurements: Errors in recognition of medical vocabulary, medical abbreviations, and general English vocabulary were compared across packages using a rigorous, standardized approach to scoring.

Results: The IBM software was found to have the lowest mean error rate for vocabulary recognition (7.0 to 9.1 percent) followed by the L&H software (13.4 to 15.1 percent) and then Dragon software (14.1 to 15.2 percent). The IBM software was found to perform better than both the Dragon and the L&H software in the recognition of general English vocabulary and medical abbreviations.

Conclusion: This study is one of a few attempts at a robust evaluation of the performance of continuous speech recognition software. Results of this study suggest that with minimal training, the IBM software outperforms the other products in the domain of general medicine; however, results may vary with domain. Additional training is likely to improve the out-of-box performance of all three products. Although the IBM software was found to have the lowest overall error rate, successive generations of speech recognition software are likely to surpass the accuracy rates found in this investigation.




This article has been cited by other articles:


Home page
J. Am. Med. Inform. Assoc.Home page
A. D. Harris, J. C. McGregor, E. N. Perencevich, J. P. Furuno, J. Zhu, D. E. Peterson, and J. Finkelstein
The Use and Interpretation of Quasi-Experimental Studies in Medical Informatics
J. Am. Med. Inform. Assoc., January 1, 2006; 13(1): 16 - 23.
[Abstract] [Full Text] [PDF]


Home page
American Journal of Medical QualityHome page
P. Rao, A. Andrei, A. Fried, D. Gonzalez, and D. Shine
Assessing Quality and Efficiency of Discharge Summaries
American Journal of Medical Quality, November 1, 2005; 20(6): 337 - 343.
[Abstract] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
D. N. Mohr, D. W. Turner, G. R. Pond, J. S. Kamath, C. B. De Vos, and P. C. Carpenter
Speech Recognition as a Transcription Aid: A Randomized Comparison With Standard Transcription
J. Am. Med. Inform. Assoc., January 1, 2003; 10(1): 85 - 93.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
S. M. Borowitz
Computer-based Speech Recognition as an Alternative to Medical Transcription
J. Am. Med. Inform. Assoc., January 1, 2001; 8(1): 101 - 102.
[Abstract] [Full Text]

eLetters:

Read all eLetters

Were environmental factors studied?
Joseph Foss
JAMIA Online, 7 Feb 2001 [Full text]
Higher Speech Recognition Accuracy with Language Models
James M Maisel
JAMIA Online, 30 Oct 2001 [Full text]
Is Minimal Training sufficiently predictive of the accuracy levels achievable in the Real World?
Gowthaman G
JAMIA Online, 18 Mar 2002 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Medical Informatics Association.